94201 Emergency Vent and Manhole Cover (with Expanda-Seal™)
An economical solution to present day emergency venting requirements. It is designed to relieve excessive internal pressure in liquid storage tanks while providing excellent protection against costly tank roof rupture repair. The Expanda-Seal™ design also decreases product leakage below actual set point. The standard design is available in 20″ & 24″ flange.
- Available with Expanda-Seal™ Option
- Easy installation, convenient handling
- 20″ and 24″ opening – 20″ and 24″ flanges
- API 650 or 150 lb ANSI compatibility
- DIN sizes available
The Shand & Jurs Model 94201 Emergency Vent and Manhole Cover with Expanda-Seal™ is an economical solution to present day emergency venting requirements. It is designed to relieve excessive internal pressure in liquid storage tanks while providing excellent protection against costly tank roof rupture repair. The Expanda-Seal™ design also decreases product leakage below actual set point. The standard design is available in 20″ & 24″ flange.
The Model 94201 is available with low base for liquid overflow. When specified, elongated guides and special stops can be provided to limit pallet lift. The pallet guide is deep enough to assure proper reseating of pallet after pressure relief at lower overpressures. Pallet will reseat when tank pressure drops below set pressure.
For tank venting or examination, the pallet may be removed from its base offering a clear unobstructed passage. A retaining cable is provided to attach the pallet to the base.
-

94126 Pressure Vent
Shand & Jurs, Tank Fittings, Flame Arrestors, Valves & ACC, Conservation Vents, Conservation Vents, L&J Technology, Pressure, Vacuum Vents, Pressure, Vacuum VentsDesigned to relieve pressure on low pressure storage tanks, and is ideally suited as a low cost rim vent on floating roof tanks. Suitable as an auxiliary pressure or emergency vent on small low pressure tanks. Available in a 6-inch size only, with screwed connection. -

94040 Spring Loaded Conservation Vent (Pressure-Vacuum)
Shand & Jurs, Tank Fittings, Flame Arrestors, Valves & ACC, Conservation Vents, Conservation Vents, L&J Technology, Pressure, Vacuum Vents, Pressure, Vacuum Vents
94040 Spring Loaded Conservation Vent (Pressure-Vacuum)
Shand & Jurs, Tank Fittings, Flame Arrestors, Valves & ACC, Conservation Vents, Conservation Vents, L&J Technology, Pressure, Vacuum Vents, Pressure, Vacuum VentsMeets the need of higher pressure settings required on storage tanks (ideally suited when blanketed with nitrogen or other inert gas), process vessels and piping common to the petroleum, chemical and petro-chemical industries. -

94308 Miniature Flame Arrester
Shand & Jurs, Tank Fittings, Flame Arrestors, Valves & ACC, Flame, Deflagration & Detonation Arresters, Flame, Deflagration & Detonation Arrestors, L&J Technology
94308 Miniature Flame Arrester
Shand & Jurs, Tank Fittings, Flame Arrestors, Valves & ACC, Flame, Deflagration & Detonation Arresters, Flame, Deflagration & Detonation Arrestors, L&J TechnologyPlays an integral function on small storage tanks and drums where low flash point solvents must be protected against exterior sources of ignition. This arrester also allows vapor pressure to be released into the atmosphere. -

94065 Emergency Vent and Manhole Cover Fiberglass (Pressure and Vacuum)
Shand & Jurs, Tank Fittings, Flame Arrestors, Valves & ACC, L&J Technology, Pressure, Vacuum Vents, Pressure, Vacuum Vents
94065 Emergency Vent and Manhole Cover Fiberglass (Pressure and Vacuum)
Shand & Jurs, Tank Fittings, Flame Arrestors, Valves & ACC, L&J Technology, Pressure, Vacuum Vents, Pressure, Vacuum VentsDesigned to provide emergency venting and vacuum relief of low-pressure storage tanks and vessels. Provide quick, easy access for tank inspection and maintenance. When the tank is exposed to abnormal internal pressure or vacuum beyond the capability of the conservation vent, the manhole protects the tank against costly rupture.